Solvent
Delivery System
|
|
|
|
1.
ProStar 210 °ú PrepStar 218 
|
|
|

|
|
ProStar
210°ú PrepStar 218 solvent delivery ¸ðµâÀº
´Ù¾çÇÑ À¯¼ÓÀ¸·Î ¸ðµç ºÐ¼® ºÐ¾ß¿¡ Àû¿ëÀÌ
°¡´ÉÇÕ´Ï´Ù. ºÎµå·´°í Á¤È®ÇÑ ¿ë¸ÅÈ帧°ú ½Ã½ºÅÛ
¾Ð·ÂÀº ³»ºÎ¿¡ ¼³Ä¡µÈ ¾Ð·Â À¯´Ö¿¡ ÀÇÇØ À¯ÁöµË´Ï´Ù.
ProStar 210Àº microbore, ÀüÅëÀûÀÎ
analytical, ±×¸®°í ÃÖ°í 100mL/min±îÁöÀÇ
Preparative À¯·®¿¡ ÀÌ»óÀûÀÔ´Ï´Ù. PrepStar
218Àº 200mL/minÀ̳ª ÃÖ°í 8700psiÀÇ backpressure¸¦
¿ä±¸ÇÏ´Â ¾îÇø®ÄÉÀ̼ǿ¡¼ ¼±ÅÃÇÒ ¼ö ÀÖ½À´Ï´Ù.
|
|
|
|
|

|
|
»ç¿ëÀÚ
ÆíÀǸ¦ °í·ÁÇÑ Pump head´Â ¼ÕÀ¸·Î Ŭ·¥ÇÁ
¸¸À» Ç®¾îÁÜÀ¸·Î½á ½±°Ô ±³È¯ÇÒ ¼ö ÀÖ´Ù.
|
|
|
|
|
´Ù¾çÇÑ
ÀçÁú ¿É¼Ç
PEEK¿Í
ƼŸ´½(Titanium) pump head°¡ À¯Ã¼µéÀÌ Áö³ª°¡´Â °¢ ¸ðµâ¿¡¼
³ª¿Ã °¡´É¼ºÀÌ ÀÖ´Â ¾ÆÁÖ ÀûÀº ¾çÀÇ ±Ý¼Ó
ÀÌ¿ÂÀ¸·Î ºÎÅÍ biological ½Ã·á¸¦ º¸È£ÇÒ ¼ö ÀÖµµ·Ï ÇØ
ÁÝ´Ï´Ù.
´Ù¾çÇÑ
±¸¼º Isocratic¿¡¼
¸ÖƼ-¸ðµâ °í¾Ð gradient mixing ½Ã½ºÅÛ±îÁö, ProStar 210°ú
PrepStar 218Àº ½ÇÇè½Ç ¿ä±¸¿¡ ¸Â°Ô ½±°Ô
±¸¼ºÇÒ ¼ö ÀÖ½À´Ï´Ù. ºÐ¼®ÀÚÀÇ ¿ä±¸¿¡ µû¶ó quaternary
gradient¸¦ À§ÇØ ÃÖ´ë 4´ëÀÇ solvent delivery¸ðµâÀ» ÀåÂøÇÒ ¼ö ÀÖ½À´Ï´Ù.

|
|
|
2.
ProStar 220/230/240 Ternary Solvent Delivery Module
 
|
|
|

|
|
Choose
the 220 (Isocratic), 230 (Ternary) or 240(Quaternary)
best suited to your laboratory's needs.
All of these models feature a paten ted pump
design that offers unequaled reliability
and ease of use.
|
|
|
|
|
Cost-Effective
Time and money saved -- Neither vacuum degassing nor
helium sparging are needed.
Pump cavitation eliminated -- Patented pump design features
exclusive mechanical inletvalve,
rapid fill stroke, and high pressure mixing. Over
99% uptime achieved - Maintenance or repair rarely needed.
Pump stroke counter allows
scheduling of routine maintenance. Extremely
easy routine maintenance -- With multilevel diagnostics
and accessible compo nents, pumps can be overhauled in
less than 30 minutes.
Peak
Performance
Gradient
pumps offer selectable one-, two-, or four-stroke proportioning
is available to optimize gradient precision on long,
shallow gradients while minimizing gradient delay volu
me
on steep, fast gradients.
Reliable
results -- Intelligent design, including electronic
flow and in-line, high-speed proportio ning valves, assures
accurate and reproducible results. GLP
compliance -- Run-and-error logs maintain a complete
audit trail of operating parameters, set points, errors,
and faults. Built-in
automations -- Up to five methods can be built and stored
at the pump. Choose the appropriate method with a single
keystroke.

|
|
|
3.PrepStar SD-1 -
Analytical to Prep  |
|
|

|
|
Direct
linear scale-up with Star Workstation software
for data handl ing and report generation
Extremely
accurate flow rates over wide dynamic ranges
with high pressure capabilities for 50,
200, and 500 mL/min pump heads
Pulse-free
flow from 0.001 mL/min to 3200 mL/min with
fivediffere nt heads
For
production requirements, use LC ReSponder
process control software and the PrepStar
530 module
|
|
|
|
|

|
|
|
|
|
|
|
|
|

|
|
Isocratic Pump ALPHA10
º» ÆßÇÁ´Â LCÀÇ ºÐ¼® ½ÇÇè¿¡
ÀûÇÕÇϵµ·Ï °í¾ÈµÇ¾ú½À´Ï´Ù. À¯¼ÓÀº
0.01-10ml/minÀÌ¸ç ¾Ð·ÂÀÇ ÇѰè´Â 40MPa(5800psi)ÀÔ´Ï´Ù.
ÁÖ pump head¿Í º¸Á¶
pump head´Â Áö¸§ 1/8¡° ÇǽºÅæ°ú ¿¬¼ÓÇÏ¿©
°á ÇյǾî ÀÖ½À´Ï´Ù.
ÀüÀÚÁ¦¾î,
ÆßÇÁ ±¸µ¿, ÇǽºÅæÀÇ ¿ÏÃæ, Ä· »þÇÁÆ®, ¾Ð·Â
º¯È¯±â, ±×¸®°í üũ
¹ëºêµîÀÇ Çõ½ÅÀûÀÎ °³³äµéÀº ±âÁ¸ÀÇ
LCD4020.3 ¸ðµ¨°ú ºñ±³ ÇÏ¿©
º¸´Ù Áøº¸µÈ ±â´É¼º°ú Çâ»óµÈ ½Å·Ú¼ºÀ» º¸ÀåÇÕ´Ï´Ù.
|
|
|
|
|
|
|
|

|
|
Isocratic Pump ALPHA50
º» ÆßÇÁ´Â LCÀÇ ºÐ¼®°ú
ºÐÃë ½ÇÇè¿¡ ÀûÇÕÇϵµ·Ï Á¦À۵Ǿú½À´Ï´Ù.
À¯¼ÓÀº 0.05-50ml/minÀ̸ç
¾Ð·ÂÀÇ ÇѰè´Â 30MPa(4400psi)ÀÔ´Ï´Ù.
Àú¾Ð¿¡¼ÀÇ ¾ÈÁ¤ÀûÀÎ ÀÛµ¿À¸·Î
analytical application¿¡ ¶ÇÇÑ »ç¿ëµÉ
¼ö ÀÖ½À´Ï´Ù. Áö¸§ 3/8¡°
ÇǽºÅæÀÌ µÎ °³ÀÇ pump head¿Í º´·Ä·Î °áÇÕ
µÇ¾î ÀÖ½À´Ï´Ù.
ÀüÀÚÁ¦¾î,
ÆßÇÁ ±¸µ¿, ÇǽºÅæÀÇ ¿ÏÃæ, Ä· »þÇÁÆ®, ¾Ð·Â
º¯È¯±â, ±×¸®°í üũ
¹ëºêµîÀÇ Çõ½ÅÀûÀÎ °³³äµéÀº ±âÁ¸ÀÇ
LCD4020.7 ¸ðµ¨°ú ºñ±³ ÇÏ¿©
º¸´Ù Áøº¸µÈ ±â´É¼º°ú Çâ»óµÈ ½Å·Ú¼ºÀ» º¸ÀåÇÕ´Ï´Ù.
|
|
|
|
|
|
|
|

|
|
Isocratic Pump ALPHA100
º» ÆßÇÁ´Â LCÀÇ ºÐÃë ½ÇÇè¿¡
ÀûÇÕÇϵµ·Ï Á¦À۵Ǿú½À´Ï´Ù. À¯¼ÓÀº 0.1-100ml/minÀ̸ç
¾Ð·ÂÀÇ ÇѰè´Â 15MPa(2200psi)ÀÔ´Ï´Ù.
Áö¸§ 3/8¡° ÇǽºÅæÀÌ µÎ
°³ÀÇ pump head¿Í º´·Ä·Î °áÇյǾî ÀÖ½À´Ï´Ù.
ÀüÀÚÁ¦¾î,
ÆßÇÁ ±¸µ¿, ÇǽºÅæÀÇ ¿ÏÃæ, Ä· »þÇÁÆ®, ¾Ð·Â
º¯È¯±â, ±×¸®°í üũ
¹ëºêµîÀÇ Çõ½ÅÀûÀÎ °³³äµéÀº ±âÁ¸ÀÇ
LCD4020.7 ¸ðµ¨°ú ºñ±³ ÇÏ¿©
º¸´Ù Áøº¸µÈ ±â´É¼º°ú Çâ»óµÈ ½Å·Ú¼ºÀ» º¸ÀåÇÕ´Ï´Ù.
|
|
|
|
|
|
|
|

|
|
Gradient Pump BETA
10
º» ÆßÇÁ´Â ¿¬±¸½Ç¿¡¼ÀÇ
´Ù¾çÇÑ LC ºÐ¼® ½ÇÇè¿¡ ÀûÇÕÇϵµ·Ï Á¦ÀÛµÇ
¾ú½À´Ï´Ù. Àú¾ÐÀ¸·Î 3°³ÀÇ
¿ë¸Å¸¦ È¥ÇÕÇÏ¿© »ç¿ëÇÒ ¼ö ÀÖÀ¸¸ç À¯¼ÓÀº
0.01-10ml/min, ¾Ð·ÂÀÇ
ÇѰè´Â 40MPa(5800psi)ÀÔ´Ï´Ù. ÁÖ
pump head¿Í º¸Á¶ pump head´Â Áö¸§ 1/8¡°
ÇǽºÅæ°ú ¿¬¼ÓÇÏ¿© °á ÇյǾî
ÀÖ½À´Ï´Ù.
ÀüÀÚÁ¦¾î,
ÆßÇÁ ±¸µ¿, ÇǽºÅæÀÇ ¿ÏÃæ, Ä· »þÇÁÆ®, ¾Ð·Â
º¯È¯±â, ±×¸®°í üũ
¹ëºêµîÀÇ Çõ½ÅÀûÀÎ °³³äµéÀº ±âÁ¸ÀÇ
LCD4020.3 ¸ðµ¨°ú ºñ±³ ÇÏ¿©
º¸´Ù Áøº¸µÈ ±â´É¼º°ú Çâ»óµÈ ½Å·Ú¼ºÀ» º¸ÀåÇÕ´Ï´Ù.
|
|
|
|
|
|
|
|

|
|
Gradient Pump BETA
50
º» ÆßÇÁ´Â LCÀÇ ºÐ¼®°ú
ºÐÃë ½ÇÇè¿¡ ÀûÇÕÇϵµ·Ï Á¦À۵Ǿú½À´Ï´Ù.
Àú¾ÐÀ¸·Î 3°³ÀÇ ¿ë¸Å¸¦
È¥ÇÕÇÏ¿© »ç¿ëÇÒ ¼ö ÀÖÀ¸¸ç À¯¼ÓÀº 0.05-50ml/minÀ̸ç
¾Ð·ÂÀÇ ÇѰè´Â 30MPa(4400psi)ÀÔ´Ï´Ù.
Àú¾Ð¿¡¼ÀÇ ¾ÈÁ¤ÀûÀÎ ÀÛµ¿À¸·Î
analytical application¿¡ ¶ÇÇÑ »ç¿ëµÉ
¼ö ÀÖ½À´Ï´Ù. Áö¸§ 3/8¡°
ÇǽºÅæÀÌ µÎ °³ÀÇ pump head¿Í º´·Ä·Î °áÇÕ
µÇ¾î ÀÖ½À´Ï´Ù.
ÀüÀÚÁ¦¾î,
ÆßÇÁ ±¸µ¿, ÇǽºÅæÀÇ ¿ÏÃæ, Ä· »þÇÁÆ®, ¾Ð·Â
º¯È¯±â, ±×¸®°í üũ
¹ëºêµîÀÇ Çõ½ÅÀûÀÎ °³³äµéÀº ±âÁ¸ÀÇ
LCP50K ¸ðµ¨°ú ºñ±³ÇÏ¿© º¸´Ù
Áøº¸µÈ ±â´É¼º°ú Çâ»óµÈ ½Å·Ú¼ºÀ» º¸ÀåÇÕ´Ï´Ù.
|
|
|
|
|

|
|
|
|
|
|
|
|
|
|
|